HyTechWorks©2013 – V3.1 27
Click on “X Axis” button on the upper right corner. Then fill in “Ster per”
(mm/inch) according to the following equation
step motor steps per revolution · driver microstep setting
screw pitch
For example, the step has 200 steps per revolution. The driver microstep is 20.
The screw pitch us 4mm. Then 1000 should be filled in “Set per” box.
“Velocity” is the maximum distance X-axis is allowed to move per minute. It is the
maximum speed of G0 code. It also limits the maximum value for F code. The
machine mechanical and control system performance limit the “Velocity”, as well
as the “Acceleration” value after it.
The pulse width settings are not used by HyCNC-4P. Press “SAVE AXIS SETTINGS”
to save X-axis settings. Then do same for “Y Axis”, “Z Axis” and “A Axis”.
The jogging can be used to test axis settings. Press “TAB” key on the keyboard to
show jogging window as the following figure. First make sure Mach3 is not in
“RESET” state by checking “RESET” button on the lower left corner not flashing
Komentarze do niniejszej Instrukcji