3 Connection diagrams
3.1 Wiring of limit switches
Mk3 controller has 8 designated limit switch inputs. In software you can set which wiring method
is used. You can use 'Normal' or 'Single Input' method of wiring.
-When 'Normal' method is used, each axis limit switch has its designated limit pin.
-When 'Single input' method is used both limit switches are connected to one limit pin.
Since Mk3 controller does not have screw type connector mounted on the board, you can use Planet-
CNC 16-pin adapter which comes in great help when wiring limit switches:
Pin description of 16-pin adapter board when connected to Mk3 Limit connector:
Bellow are wiring plans and pictures that demonstrate wiring of limit switches when 'Normal' or 'Single
input' method is used.