AXISF41MainUnit
TechnicalSpecifications
Connectors
I/OConnector
6-pincongurableterminalblockfor:
Auxiliarypower(DCoutput)
DigitalInput
DigitalOutput
0VDC(-)
1 2 3 4 5 6
FunctionPinNotes
Specications
0VDC(-)
1
0VDC
DCoutput
2
Canbeusedtopowerauxiliaryequipment.
Note:Thispincanonlybeusedaspowerout.
3.3VDC
Maxload=250mA
DigitalinputConnecttopin1toactivate,orleaveoating
(unconnected)todeactivate.
0tomax40VDC Congurable
(InputorOutput)
3–6
DigitaloutputConnectedtopin1whenactivated,oating
(unconnected)whendeactivated.Ifusedwithaninductive
load,e.g.arelay,adiodemustbeconnectedinparallelwith
theload,forprotectionagainstvoltagetransients.
0tomax40VDC,opendrain,
100mA
3.3 V max 250 mA
1
2
A
B
A
I/Oconguredasinput
B
I/Oconguredasoutput
59