LNC-M8000
Expression
寶元數控精密股份有限公司 191
LNC Technology Co., Ltd.
7.5 EXIT_FOR
Method:
FOR variables=loop’s initial value or calculating formula TO loop’s endingl value or calculating
formula STEP loop acccumulated value or calculating formula
EXIT_FOR
END_FOR
Description:leave FOR loop
Example:
G0 X0.
FOR #1=11 TO 23
G0 X#1;
IF(#1>15)
EXIT_FOR; /* when #1=16, leave loop */
END_IF
END_FOR
M0; /* X axis final movement position 16mm,#1final is 16 */
M30
7.6 WHILE
Method:
WHILE(conditions described)
Data Process;
END_WHILE
Description:WHILE loop
Example:
G0 X0.
#1=2
WHILE(#1<10)
G0 X#1
#1=#1+1
END_WHILE
M0; /* X AXIS FINAL MOVEMENT POSITION9mm,#1final is 10 */
M30
Komentarze do niniejszej Instrukcji